[one_third last=”no” spacing=”yes” center_content=”no” hide_on_mobile=”no” background_color=”” background_image=”” background_repeat=”no-repeat” background_position=”left top” hover_type=”none” link=”” border_position=”all” border_size=”0px” border_color=”” border_style=”” padding=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”” animation_speed=”0.1″ animation_offset=”” class=”” id=””]

T300-10-80KVA-300x300

[button link=”http://sabmatic.co/wp-content/uploads/2016/pdfs/PROWAVE-T300-10-80KVA.pdf” color=”green” size=”” stretch=”yes” type=”flat” shape=”square” target=”_blank” title=”” gradient_colors=”#81d742|” gradient_hover_colors=”|” accent_color=”” accent_hover_color=”” bevel_color=”” border_width=”1px” icon=”fa-download” icon_position=”left” icon_divider=”no” modal=”” animation_type=”bounce” animation_direction=”down” animation_speed=”0.1″ animation_offset=”” alignment=”center” class=”” id=””]Technical Specifications[/button][/one_third][two_third last=”yes” spacing=”yes” center_content=”no” hide_on_mobile=”no” background_color=”” background_image=”” background_repeat=”no-repeat” background_position=”left top” hover_type=”none” link=”” border_position=”all” border_size=”0px” border_color=”” border_style=”” padding=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”” animation_speed=”0.1″ animation_offset=”” class=”” id=””]

[tabs tab1=”Description” tab2=”Key Points” tab3=”Key Features” ]
[tab id=1]
Prowave T300
Uninterruptible Power Supplies
3phase in/3 phase out (10-80KVA)

Prowave 300 Series are, True online, Double conversion UPS Systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sine wave output to critical load.

[/tab]
[tab id=2]

  • Voltage: 230/ 400VAC 3Phase, +N/-15%
  • Bypass Voltage: 230/ 400VAC 3Phase, +/-10%
  • Input Frequency: 50Hz(60Hz on request) +/- 5%
  • Output Voltage: 230/ 400VAC 3Phase, +N
  • Output Frequency: 50Hz (60Hz on request)
  • Transformer: Galvanic isolation transformer at the input (in external cabinet)
  • Parallel Operation: 1+3 System (not standby, redundant, symmetric parallel)

[/tab]
[tab id=3]

  • Galvanic isolation transformer at the inverter output
  • Efficiency up to 91%
  • Statistics and maintenance by-pass
  • Emergency stop utility, built in
  • Advanced LCD panel providing detailed information (input/output voltage, charging current, interior temperature) and setting user selectable parameters.
  • Microprocessor : Main controller board, rectifier board and optional parallel control board
  • 64 recorded event history
  • Calendar and time indicator
  • Advance automatic and manual battery test system
  • Non linear load driving capability
  • Simulation mode for testing dry contact outputs
  • Dial up modem direct connection and AT command set built in.
  • RS232 and dry contacts for communication and remote monitoring
  • Input / Output customization, possible
  • SNMP compatible with international standards
  • 1 year full warranty
  • Supply of spare parts guaranteed for 10 years
  • Designed and manufactured under TUV-ISO9001 certification.